Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter

FEATURES ● The 4156 PR is used to identify the leads of a diconnected motor so    that when the motor is in true phase sequence, it will run in the    desired direction.     SPECIFICATIONS       Measuring ranges 0~200kΩ Test leads AL-34 length : 50cm Dimensions 250(L) × 190(W) × 110(D)mm Weight (battery included) Approx. 1280g Power source 1.5V (AA) × 2 Safety standard EN 61010-1 EN 61326-1

FEATURES ● Safely operates at low voltage       ● Measures system voltage.● Measures capacitance of test point if system voltage is known.● Checks phase rotation of cables.● Phases out cables.● Rugged - comes with portable case.● Operates from potential test point of elbow connec-tors.● Battery operated.      SPECIFICATIONS       Voltage ranges 0~16kV / 0~32kV Accuracy ±8% (exclusive of tap capacitance variations) Tap capacitance setting 0.4 to 3.0 pF continuous per channel Frequency 50 or 60 Hz Dimensions 250(L) × 190(W) × 110(D)mm Weight (battery included) Approx. 1420g Power source 1.5V (AA) × 4 Safety standard EN 61326-1

FEATURES ● Designed for measuring AC current, AC voltage resistance and DC   voltage .● Rotary scale which presents only one scale in windows at one time   to avoid any possible reading errors.● Pointer lock function freezes the reading in dimly lit or hard to reach   places.● Ω range ideal for checking the continuity or relays, transformers and   motor coils.     SPECIFICATIONS         AC A 6 / 15 / 60 / 150 / 300A ±3% of F.S.(50/60Hz) AC V 300 / 600V ±3% of F.S. DC V 75V ±3% of F.S.   Ω 2kΩ ±3% of Scale length Frequency response 50 / 60Hz for ACA 6A 50-400Hz for ACA 15 / 60 / 150 / 300A Dimensions 230(L) × 72(W) × 37(D)mm Conductor size 38mm Max. Weight (battery Included) Approx. 420g Safety standard EN 61010-1 CAT II 600V EN 61010-2-32

FEATURES ● Rotary scale which presents only one scale in windows at one time   to avoid any possible reading errors.● Pointer lock function freezes the reading in dimly lit or hard to reach   places.● Ω range ideal for checking the continuity or relays, transformers and   motor coils.     SPECIFICATIONS         AC A 6 / 30 / 60 / 300 / 600A ±3% of F.S.(50/60Hz) AC V 150 / 300 / 600V ±3% of F.S. DC V   ──   Ω 2kΩ ±3% of Scale length Frequency response 50 / 60Hz for ACA 6A 50-400Hz for ACA 30 / 60 / 300 / 600A Dimensions 230(L) × 72(W) × 37(D)mm Conductor size 38mm Max. Weight (battery Included) Approx. 420g Safety standard EN 61010-1 CAT II 600V EN 61010-2-32

503 Service Unavailable

Service Unavailable

The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

Additionally, a 503 Service Unavailable error was encountered while trying to use an ErrorDocument to handle the request.